Product
Catalog: Fiber Optic Leak Detector
Protecting your
investment in transmission equipment is a major consideration in today's
high tech applications. Altronic Research has developed the Fiber Optic
Interlock Monitor or Leak Detector exactly for those concerns.
The Fiber Optic
Interlock Monitor is designed for use in high RF environments and senses
the presence of any liquid where sensors are installed to protect wave
guides, coaxial lines, filters, combiners, and dummy loads. The sensors
detect fault conditions and will shut the transmitter off before extensive
damage can occur to ancillary equipment. Its simplified design allows
user installation and is expandable to multi-channel / multi-function
operation.

Fiber Optic Interlock
Monitor
- Designed for
use in high RF environments
- Input Power:
110 to 230 Vac 50/60 Hz
- High Speed
- Interlock Interface:
Transmitter, Pump, Remote Indicator
- Control Panel:
Available in NEMA or Rack Mount configurations
- Simplified design
allows user installation.
- Expandable to
multi-channel / multi-function operation.
- Detects fault
conditions and shuts the transmitter off before extensive damage is
done.
- Plastic fiber
optic fiber may be installed and maintained without the need for special
tools.
Leak Detection:
- Senses the presence
of any liquid
- Noise immune
modulated/synchronous detector scheme design
- Failsafe configuration
-- if the unit is not operational the interlock will not operate.
- Flush internal
1/4 pipe Gyroloke fiber interface
- Protect waveguides,
coaxial lines, filters, combiners and dummy loads
- Proper installation
has minimal effect on the VSWR
- Sealed / pressurized
operation
- May be used as
interlock to shut down the operation of the pump during a fault condition.
- This device will
disable the transmitter enable signal to the interlock when a leak
occurs.
Arc Detection*:
- Fiber optic detection.
- Detects optical
energy associated with an arc.
- Detects arc faults
in waveguide, coaxial lines, filters, combiners, and dummy loads.
- Sealed / pressurized
operation
- Flush internal
1/8 pipe Gyroloke fiber interface
- Visual and audible
alarms available for both Arc and Leak.
* Consult factory
|
 |